Problem resolved in Alpha Station version 1.0.0.3
I am trying to view the configuration of the Enterprise Wireless Vibration Sensor using Alpha Station multiple times, however an error keeps popping. Steps that I have done include, restarting my computer, unplugging the zigmo modem, pressing the reset button on the sensor and plugging out and in the PS jumper.
Error message is as follows
See the end of this message for details on invoking
just-in-time (JIT) debugging instead of this dialog box.
************** Exception Text **************
System.ArgumentOutOfRangeException: Value of ‘10’ is not valid for ‘Value’. ‘Value’ should be between ‘Minimum’ and ‘Maximum’.
Parameter name: Value
at System.Windows.Forms.NumericUpDown.set_Value(Decimal value)
at Alpha.frmSensorConfiguration.ReadConfig()
at Alpha.frmSensorConfiguration.Timer1_Tick(Object sender, EventArgs e)
at System.Windows.Forms.Timer.OnTick(EventArgs e)
at System.Windows.Forms.Timer.TimerNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
************** Loaded Assemblies **************
mscorlib
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3260.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.NET/Framework/v4.0.30319/mscorlib.dll
Alpha Station
Assembly Version: 1.0.0.0
Win32 Version: 1.0.0.0
CodeBase: file:///C:/Users/Engineer-2/AppData/Local/Apps/2.0/59QER3RN.8W2/Y0DBNPW2.JCP/alph…tion_0000000000000000_0001.0000_e8787f52ac83e044/Alpha%20Station.exe
Microsoft.VisualBasic
Assembly Version: 10.0.0.0
Win32 Version: 14.7.3062.0 built by: NET472REL1
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/Microsoft.VisualBasic/v4.0_10.0.0.0__b03f5f7f11d50a3a/Microsoft.VisualBasic.dll
System
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3314.0 built by: NET472REL1LAST_B
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System/v4.0_4.0.0.0__b77a5c561934e089/System.dll
System.Core
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Core/v4.0_4.0.0.0__b77a5c561934e089/System.Core.dll
System.Windows.Forms
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Windows.Forms/v4.0_4.0.0.0__b77a5c561934e089/System.Windows.Forms.dll
System.Drawing
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Drawing/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Drawing.dll
System.Configuration
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3062.0 built by: NET472REL1
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Configuration/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Configuration.dll
System.Xml
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Xml/v4.0_4.0.0.0__b77a5c561934e089/System.Xml.dll
System.Runtime.Remoting
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Runtime.Remoting/v4.0_4.0.0.0__b77a5c561934e089/System.Runtime.Remoting.dll
NCDEnterprise
Assembly Version: 2.0.6926.17133
Win32 Version: 2.0.0.0
CodeBase: file:///C:/Users/Engineer-2/AppData/Local/Apps/2.0/59QER3RN.8W2/Y0DBNPW2.JCP/alph…tion_0000000000000000_0001.0000_e8787f52ac83e044/NCDEnterprise.DLL
Microsoft.GeneratedCode
Assembly Version: 1.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Xml/v4.0_4.0.0.0__b77a5c561934e089/System.Xml.dll
System.Management
Assembly Version: 4.0.0.0
Win32 Version: 4.7.3221.0 built by: NET472REL1LAST_C
CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Management/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Management.dll
************** JIT Debugging **************
To enable just-in-time (JIT) debugging, the .config file for this
application or computer (machine.config) must have the
jitDebugging value set in the system.windows.forms section.
The application must also be compiled with debugging
enabled.
For example:
When JIT debugging is enabled, any unhandled exception
will be sent to the JIT debugger registered on the computer
rather than be handled by this dialog box.
Please assist, thank you!