Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here .

Additional physico-chemical information
  • Administrative data
  • Link to relevant study record(s)
  • Description of key information
  • Key value for chemical safety assessment
  • Additional information
  • Administrative data

    Link to relevant study record(s)

    Reference
    Endpoint:
    partition coefficient
    Type of information:
    experimental study
    Adequacy of study:
    key study
    Study period:
    This study was conducted between 24 June 2016 and 18 December 2016
    Reliability:
    1 (reliable without restriction)
    Rationale for reliability incl. deficiencies:
    guideline study
    Qualifier:
    according to guideline
    Guideline:
    EU Method A.8 (Partition Coefficient - HPLC Method)
    Version / remarks:
    EC No. 440/2008 30 May 2008
    Deviations:
    no
    Qualifier:
    according to guideline
    Guideline:
    OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
    Version / remarks:
    13 April 2004
    Deviations:
    no
    GLP compliance:
    yes (incl. QA statement)
    Type of method:
    HPLC method
    Partition coefficient type:
    octanol-water
    Analytical method:
    high-performance liquid chromatography
    Key result
    Type:
    Pow
    Partition coefficient:
    > 2 - < 3.22
    Temp.:
    20 °C
    pH:
    5 - 6
    Key result
    Type:
    log Pow
    Partition coefficient:
    > 0.3 - < 0.507
    Temp.:
    20 °C
    pH:
    5 - 6
    Details on results:
    The predicted partition coefficient determined that a flask method was the most suitable method of analysis, however due to the fast hydrolysis of the test item this method was deemed not suitable and therefore HPLC was conducted. The HPLC method uses a range of standards and as such a limit value was employed on most of the peaks obtained as their retention time was lower than the lowest calibration standard. Limit value agreed with sponsor due to the fast hydrolysis of the test item.

    The retention times of the dead time and the retention times, capacity factors (k') and log10 Pow values for the reference standards are shown in the following tables: Partition coefficient:       <2.00 to 3.22

    Conclusions:
    The partition coefficient of the test item has been determined to be in the range of less than 2.00 to 3.22, log10 Pow less than 0.3 (70.3% area) to 0.507 (29.7% area) at 20.0 ±0.5 °C.
    Executive summary:

    The general physico-chemical properties of 9-[2-(2-METHOXYETHOXY)ETHOXY]-9-[3(OXIRANYLMETHOXY)PROPYL]-2,5,8,10,13,16-HEXAOXA-9-SILAHEPTADECANE have been determined.   In the range of less than 2.00 to 3.22, log10 Pow <0.3 (70.3% area) to 0.507 (29.7% area) at 20.0 ± 0.5 °C, using the HPLC method, designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

    Description of key information

    Partition Coefficient (n-octanol/water)calculated to be in the range of less than 2.00 to 3.22, log10 Pow <0.3 (70.3% area) to 0.507 (29.7% area) at 20.0 ± 0.5 °C, using the HPLC method, designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004. For regulatory purposes the conservative estimate based on the minor peak should be used e.g. <0.507 at 20 ± 0.5 °C

    Key value for chemical safety assessment

    Log Kow (Log Pow):
    0.507
    at the temperature of:
    20 °C

    Additional information

    Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
    Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.